ISIscan version 4.4.0.13316 Update

November 11, 2011

NOTE: Do not update to ISIscan version 4.4 if you are a RINA client on a previous version. Updating to a new version will make leave your instrument unable to synchronize with the RINA server.

The following new features have been added:

Discrim analysis We have added support for DC5 discriminant models.
Fixed integration time For technicians it is possible to set a fixed integration time, so the instrument does not need to spend time on calculating the integration time. Some customers with homogenous samples can benefit a lot of this at performance (analysis time)
Improved archiving Now archiving will not include samples with lab data, and furthermore the user will get a dialog after archiving with a result report.
Reestablish instrument connection In general the stability with continuous scanning is improved a lot. One improvement is that ISIscan is able to re-establish instrument connection after it is lost e.g. if the cable for some reason are unplugged and after 5 minutes plugged in again.
Also the logging are extended to improve trouble shooting.

Additionally, the following bug fixes and program enhancements have been included in version 4.4:

  • RINA 4.3 does not have support for DC5 discriminant models
  • ISIscan Discrim: Disc column on history tab is displaying "Confidence" value for each sample and it should be displaying "uncertain" value.
  • Cannot set product code when creating a Discriminate Product Group in RINA
  • ISIscan 4.3 (critical runtime error when exiting)
  • ProFoss (Global): Out of Memory ProFoss : SQL Data Type Mismatch 1.#QNAN0"
  • Using Monitor, Save Adjustments button can slow down ISIscan performance to the point where it is unusable in certain situations
  • ISIscan database is missing the HardwareRangeUseful table Update
  • COMM: ProFoss freezing while analysing if TCP/IP socket closed.
  • Candidate 4.4.0 Auto archiving will not run if spectra storing is set to Never
  • OSI 4.4.0 Hang after scanning LIMS samples
  • Candidate 4.4.0 request that ISIscan auto archive routine ignore samples with lab data
  • Candidate 4.4.0 "This sample is a outlier. The results will not be displayed!" message is not logged by the "Disable display of system messages." Stops continuous scanning.
  • LIMS delays analysis cycle (XDS MUX w OPC). 4.4.0 XDS Rapid Liquid Analyser - temperature control failure
  • ProFoss editable IP
  • Candidate 4.4.0 WINISI Discrim.exe security issue (temp file in c:\ root directory)
  • Run Monitor with updated prediction model profile

ISIscan version 4.4 is available as a free update to all licensed users of ISIscan version 4.x.